Rice Lake Counterpart Manuel d'installation

Naviguer en ligne ou télécharger Manuel d'installation pour Mesure, test et contrôle Rice Lake Counterpart. Rice Lake Counterpart Installation manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Installation Manual

66503 IQ plus ® 355 Digital Weight IndicatorVersion 1.1 Installation Manual

Page 2

6 IQ plus 355 Installation Manual2.3.2 Load CellsTo attach cable from a load cell or junction box,remove connector J1 from the board. The connectorpl

Page 3 - Contents

Installation 72.3.4 Analog OutputIf the optional analog output module is installed,attach the output cable to connector J1 on the analogoutput board.

Page 4

8 IQ plus 355 Installation Manual2.7 Replacement PartsTable 2-4 lists replacement parts for the IQ plus 355, including all parts referenced in Figures

Page 5 - 1.0 Introduction

Installation 9Figure 2-5. IQ plus 355 Backplate and Tilt Stand AssembliesPRINTUNITSTAREGROSSNETZERO410111265816171824/4X72720/4X9/4XTo Line FilterSee

Page 6 - NORMAL MODE KEY FUNCTIONS

10 IQ plus 355 Installation ManualFigure 2-6. IQ plus 355 Enclosure and CPU Board23/4X14/4X30/8X33/8XAC power in from line filterCable tieBrown wireBl

Page 7 - 1.4 Indicator Operations

Installation 11Figure 2-7. Line Filter AssemblyFigure 2-8. Ground Post AssemblyFigure 2-9. IQ plus 355 Enclosure and OverlayAC input to CPU board JP71

Page 8 - 2.0 Installation

12 IQ plus 355 Installation Manual3.0 ConfigurationTo configure the IQ plus 355 indicator, the indicatormust be placed in setup mode. The setup switch i

Page 9 - Installation

Configuration 133.1.3 Front Panel ConfigurationThe IQ plus 355 indicator can be configured using a series of menus accessed through the indicator front

Page 10

14 IQ plus 355 Installation ManualTo select a parameter, press or to scroll left orright until the desired menu group appears on thedisplay, then

Page 11 - 2.6 Board Removal

Configuration 153.2.1 Configuration MenuFigure 3-5. Configuration MenuCONFIG MenuParameter Choices DescriptionLevel 2 submenusGRADS 10000numberGraduatio

Page 13 - Installation 9

16 IQ plus 355 Installation ManualZRANGE 1.9%100%Zero range. Selects the range within which the scale can be zeroed. The 1.9% selection is± 1.9% aroun

Page 14 - Line Filter Connection to JP7

Configuration 173.2.2 Format MenuFigure 3-6. Format MenuFORMAT MenuParameter Choices DescriptionLevel 2 submenus PRIMAR DECPNTDSPDIVUNITSSpecifies the

Page 15 - Installation 11

18 IQ plus 355 Installation ManualLevel 3 submenus Primary Units (PRIMAR Parameter)DECPNT 8888888888808.8888888.8888888.8888888.8888888.8Decimal point

Page 16 - 3.0 Configuration

Configuration 193.2.3 Calibration MenuSee Section 4.0 on page 24 for calibration procedures.Figure 3-7. Calibration Menu3.2.4 Serial MenuSee Section 7

Page 17 - SETUP MODE KEY FUNCTIONS

20 IQ plus 355 Installation Manual3.2.5 Program MenuFigure 3-9. ProgramMenuSERIAL MenuParameter Choices DescriptionLevel 2 submenusEDP BAUDBITSTERMINE

Page 18 - 0 0 0 0 0 0

Configuration 213.2.6 Print Format MenuSee Section 6.0 on page 32 for information about custom print formatting.Figure 3-10. Print Format MenuPROGRM M

Page 19 - CONFIG Menu

22 IQ plus 355 Installation Manual3.2.7 Digital Input MenuFigure 3-11. Digital Input MenuDIG IN MenuParameter Choices DescriptionLevel 2 submenusDIGIN

Page 20

Configuration 233.2.8 Analog Output MenuThe ALGOUT menu is used only if the analog output option is installed. If the analog output option is installe

Page 21 - FORMAT Menu

24 IQ plus 355 Installation Manual4.0 CalibrationThe IQ plus 355 can be calibrated using the front panel, EDP commands, or the Revolution™ configuratio

Page 22

Calibration 254.2 EDP Command CalibrationTo calibrate the indicator using EDP commands, theindicator EDP port must be connected to a terminal orperson

Page 23

Copyright © 2002 Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America. Specifications subject to change without no

Page 24 - SERIAL Menu

26 IQ plus 355 Installation Manual4.4 More About CalibrationThe following topics provide additional informationabout compensating for environmental fa

Page 25 - PROGRM Menu

EDP Commands 275.0 EDP CommandsThe IQ plus 355 indicator can be controlled by apersonal computer or remote keyboard connected tothe indicator EDP port

Page 26 - DIG IN Menu

28 IQ plus 355 Installation Manual5.1.2 Reporting CommandsReporting commands (see Table 5-2) send specificinformation to the EDP port. These commands c

Page 27 - Software

EDP Commands 29Command Description ValuesPRI.DECPNT Primary units decimal position 8.88888, 88.8888, 888.888, 8888.88, 88888.8, 888888, 888880PRI.DSPD

Page 28

30 IQ plus 355 Installation Manual5.1.5 Normal Mode CommandsThe serial transmit weight data commands (see Table 5-11) transmit data to the EDP port on

Page 29 - Calibration

EDP Commands 315.2 Saving and Transferring DataConnecting a personal computer to the IQ plus 355EDP port allows you to save indicator configurationdata

Page 30 - 4.4 More About Calibration

32 IQ plus 355 Installation Manual6.0 Print FormattingThe IQ plus 355 provides two print formats, GFMTand NFMT, that determine the format of the print

Page 31 - 5.0 EDP Commands

Print Formatting 33To change the format, use the GFMT or NFMT EDPcommand followed by an equals sign (=) and themodified print format string. For exampl

Page 32

34 IQ plus 355 Installation Manual7.0 Appendix7.1 Error MessagesThe IQ plus 355 indicator provides a number of error messages. When an error occurs, t

Page 33

Appendix 357.1.2 Using the XE EDP CommandThe XE EDP command can be used to remotely querythe IQ plus 355 for the error conditions shown on thefront pa

Page 34 - 5.1.5 Normal Mode Commands

ii IQ plus 355 Installation Manual 4.4.1 Adjusting Final Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 35 - Indicator

36 IQ plus 355 Installation Manual7.3 Continuous Output (Stream) FormatFigure 7-1 shows the continuous output format sent to the IQ plus 355 EDP or pr

Page 36 - 6.0 Print Formatting

Appendix 377.4 ASCII Character ChartUse the decimal values for ASCII characters listed inTables 7-4 and 7-5 when specifying print formatstrings on the

Page 37

38 IQ plus 355 Installation ManualTable 7-5. ASCII Character Chart (Part 2)ASCII Dec Hex ASCII Dec Hex ASCII Dec Hex ASCII Dec HexÇ 128 80 á 160 A0 19

Page 38 - 7.0 Appendix

Appendix 397.5 Front Panel Display CharactersFigure 7-2 shows the 7-segment LED character set used to display alphanumeric characters on the IQ plus 3

Page 39 - 7.2 Status Messages

40 IQ plus 355 Installation Manual7.6 Conversion Factors for SecondaryUnitsThe IQ plus 355 has the capability to mathematicallyconvert a weight into m

Page 40

Appendix 417.7 Digital FilteringThe IQ plus 355 uses averaged digital filtering to reduce the effect of vibration on weight readings. Adjustablethresho

Page 41 - 7.4 ASCII Character Chart

42 IQ plus 355 Installation Manual7.7.3 Setting the Digital Filter ParametersFine-tuning the digital filter parameters greatlyimproves indicator perfor

Page 42

Appendix 437.9 Test ModeIn addition to normal and setup modes, test modeprovides a number of diagnostic functions for the IQplus 355, including:•Displ

Page 43 - Appendix 39

44 IQ plus 355 Installation Manual7.10 Software Revision HistoryFor a complete description of recent software revisions, visit our web site at www.rlw

Page 44 - Table 7-6. Conversion Factors

Appendix 457.11 SpecificationsPowerLine Voltages 115 or 230 VACFrequency 50 or 60 HzPower Consumption 70 mA @ 115 VAC (8W)35 mA @ 230 VAC (8W)Fusing115

Page 45 - 7.7 Digital Filtering

Introduction 1 About This Manual This manual is intended for use by service techniciansresponsible for installing and servicing IQ plus ® 355digital

Page 46 - 7.8 Analog Output Calibration

46 IQ plus 355 Installation ManualIQ plus 355 Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly

Page 47 - 7.9 Test Mode

2 IQ plus 355 Installation Manual 1.2 Front Panel Keypad Figure 1-1 on page 2 shows the IQ plus 355 LED annunciators, keypad, and normal mode key fun

Page 48

Introduction 3 Table 1-1 shows which annunciators are used for all combinations of configured primary and secondary units.For example:• If the primary

Page 49 - 7.11 Specifications

4 IQ plus 355 Installation Manual 2.0 Installation This section describes procedures for connecting loadcells, digital inputs, and serial communicati

Page 50 - IQ plus 355 Limited Warranty

Installation 5 2.3.1 Cable Grounding Except for the power cord, all cables routed throughthe cord grips should be grounded against theindicator backp

Commentaires sur ces manuels

Pas de commentaire